HOME > PRODUCTION > MULTI TYPE PCB PORT CLEANER

WIPING CLEANER

MULTI TYPE PCB PORT CLEANER

自己発塵性の低いワイピングテープによりプリント基板をピンポイントにクリーニング マルチタイプPCB端子クリーナーI
タイプ 1.Desktop Type.
2.Wipe out dust on Electrode zone(terminal zone) of PCB with wiping cloth.
3.Stable cleaning assures the quality.
4.Wipe out too much dust such as attached dust, flux during transportation of the Machine.

FEATURE

1 Stable cleaning can be done by setting the optimum figure for welding pressure of wiping cloth.
   
2 Various dust can be wiped out by using Cleaning Solution together and it protects adhesion of dust again.
   
3 It can change the feeding volume of wiping cloth.
   
4 Different size works can be cleaned by replacing positioning JIG.
   
5 Dispensing volume of Cleaning Solution can be adjusted.
   
6 As Jig is placed on moving stage, this is a multi type machine which can wipe several points.

BASIC SPECIFICATIONS

1) Work
(1)Work Size Max.100mm×100mm
(2)Cleaning portion Max.10 places
2) Mechanical Section
(1)Wiping Tape Savina Minimax(Kanebo Synthetic)
(2)Width of Tape 10 - 20mm
(3)Length of Tape 47m
3) Mechanical Section
(1)Positioning for Work Pin and Outer Shape Guide
(2)Moving Stage Drive by Stepping Motor
X axis: 100mm
Y axis: 150mm
θ axis: 90 degree Revolving (Air Cylinder)
(3)Head Up and Down Air Cylinder
Welding Pressure is Adjustable by change Height and Spring
[Impositive Structure]: Adjust Impositive Pressure by Change Spring Compression.
[Head]: SUS Material, It is exchangeable to Multiple Type
(4)Tape Feeding DC Gear Motor There are Feeding Motor and Wind-up Motor.
You can change Tape Feeding Amount by changing Wind-up motor dog,
(5)Cleaning Fluid Dispenser
ON/OFF Switching with Solenoid Valve.
Quantity of Application can be Adjusted by Adjusting Knob
(6)Mechanical Section Cover -
(7)Countermeasure against Static -
(8)Trestle -
4) Control
(1)Operation Panel Operation can be done such as Start, ORG, Dispense, EMG Stop etc.
(2)Control Unit Function Choose Power ON/OFF, Manual Operation, Cleaning Program etc.
(3)Controller Programmable Controller
(4)Number of Program 3-4 Programs Register (64 steps)
*Create Minimum Pitch Position Data, It also can be Selected from Moving Pitch.
5) Utility
(1)Power Consumption AC100V 50Hz/60Hz
(2)Outer Dimension 0.5MPa